| CUSTOM
OPTIONS |
As
well as an infinite range of special lintel designs to
suit any architectural design or loading requiriment,
Supergalv lintels are available in all cavity wall styles
adapted to suit special circumstances. Please contact
our technical advisory service for details and information
on price and availability.
Examples of these special service lintels are: |
|
|
NM |
Where
the inner leaf of the cavity wall is fair-faced and the
inner flange of the lintel is not plastered, the plaster
key on this flange can be omitted.
To specify, add 'NM' to the end of the lintel
Reference: e.g. CB50NM |
|
|
ND |
To
minimise the mortar bed thickness at the end bearings,
e.g. when using stone heads and surrounds, te weather
drip on the front flange of the lintel can be omitted
To specify, add 'ND' to the end of the lintel
Reference: e.g. CB50ND |
|
|
|
CP |
Where
the underside of the lintel is completely exposed, e.g.
porches, driveways, etc., a closer plate can be welded
priorto galvanizing to provide a neat, aesthetically pleasing
finish to the soffit of the lintel.
To Specify, add 'CP' to the end of the lintel
Reference: e.g. CB50CP |
|
|
MF |
Where
the external leaf of a cavity wall is rendered, an additional
mesh plaster key can be welded to the front flange prior
to galvanizing to facilitate this.
To specify, add 'MF' to the end of the lintel
Reference: e.g. CB50MF |
|
|
U2K |
'Ultragalv
200' maximum corrosion protection with 2000g/m2
(including both sides) Zinc coating.
To specify, add 'U2K' to the end of the lintel
Reference: e.g. CB50U2K |
|
|